TECHNICAL REFERENCE DATA – PIPE
CONCRETE PLACING SYSTEM ENGINEERING DATA
ID PIPE SIZE
IN
2
3
4
5
6
in
3.1
7.1
12.6
19.6
28.3
2
Cross-Sectional Area (inside the pipe)
2
ft
.02
.05
.09
.14
.20
3
ft
2.0
5.0
9.0
14.0
20.0
Volume of Concrete per 100ft section of pipe
3
yd
.07
.19
.33
52
.74
Weight of concrete per 10 ft section of pipe at 150lbs per cu.ft.
lbs
30
75
135
210
300
3
Pipe Length per yd of concrete
ft
1,350
540
300
193
135
CONCRETE PLACING LINE WEIGHTS
INSIDE DIAMETER (in/mm)
WALL THICKNESS
LINE EMPTY (lbs/Kg)
CONCRETE ONLY (lbs/Kg)
TOTAL PER FT (lbs/Kg)
TOTAL WEIGHT PER 10 FT. SECTION (lbs/kg)
2/50.8
11ga. / 3mm 2.9 / 1.3
3.3 / 1.5
6.2 / 2.8
62 / 28
3/76.2
11ga. / 3mm 4.1 / 1.9
7.4 / 3.4
11.5 / 5.2
115 / 52.2
4/102
11ga. / 3mm 5.5 / 2.5
13.1 / 5.9
18.6 / 8.4
186 / 84.4
5/127
11ga. / 3mm 6.9 / 3.1
20.5 / 9.3
27.4 / 12.4
274 / 124.3
5/127
9 ga. / 3.8mm 7.4 / 3.4
20.5 / 9.3
27.9 / 12.6
279 / 126.6
5/127
7 ga. / 4.6mm 10.4 / 4.7
20.5 / 9.3
30.9 / 14
309 / 140.2
5/127
.250
14.0 / 6.4
20.5 / 9.3
34.5 / 15.6
345 / 156.5
5/127
.500
29.4 / 13.3
20.5 / 9.3
49.9 / 22.6
498 / 226
6/152
11ga. / 3mm 8.5 / 3.9
29.5 / 13.4
38.0 / 17.2
380 / 172.4
6/152
9 ga. / 3.8mm 10.0 / 4.5
29.5 / 13.4
39.5 / 17.9
395 / 179
6/152
.250
16.7 / 7.6
29.5 / 13.4
46.2 / 20.9
461 / 209
Notes: 11 ga. = .120" / 3.0mm Wall; 9 ga. = .150" / 3.8mm Wall; 7 ga. = .180" / 4.6mm Wall